| Test
Item |
Test
Data |
| Lock Torque |
25~30Nm (221~265 in.lb) for Ceramic
Cartridge Model |
| 35~40Nm (310~354 in.lb) for Stem Model |
| Lever Torque |
20Nm (177 in.lb) |
| Ceramic Hardness |
1400HV |
| Ceramic Flatness |
≦ 0.6um |
| Ceramic Roughness |
Ra0.15um |
| Ceramic Contact Surface Area |
60~80% |
| Switch Torque |
≦ 0.8Nm (7 in.lb) at 8.6bar (125psi) |
| ≦ 1Nm (8.8 in.lb) at 8.6bar
(125psi) just for Joystick Model |
| Temperature Range |
4~90℃ (39.2~194℉) |
| Working Pressure |
1.4~14bar (21~204psi) |
| Max. Pressure Resistance |
35bar (500psi) |
| Flow Rate |
≦ 8.3L/min (0.5gpm) at 4.2bar (60psi) for SL15T,
10T, SC15T, Joystick15, Stem15 Model |
| ≦ 15L/min (0.9gpm) at 4.2bar
(60psi) for SL20T, 25T, Joystick20, Stem20, Diverter Model
|
| Air Pressure Test (100%) |
8bar (117psi) |
| Endurance Test |
500,000cycles ASME A 112.18.1 (70,000cycles EN817) |